JZYW-200A Surface Determination Tester/Surface Tester For Liquid
Applicability:
Liquid tension is measured via physical methods. This type of tensiometer finds wide application in scientific research institutions, universities, and water & power sectors.
Performance:
Technical parameter:
Model | JZYW-200A | |
Display mode | Digital | |
Measuring range | 0~199.9mN/m | |
Measuring mode | Automatic | |
Min. resolution | 0.1mN/m | |
Pt ring radius | 9.55mm | |
Pt wire radius | 0.3mm | |
Dimensions(L*W*H) | 400mm×220mm×350mm | |
Frame Net Weight | 15Kg | |
Standard accessory | Frame, platinum ring, Torsion wire, Pothook, Glass cup, 500mg standard weight, manual etc. |
Configuration:
Name | Quantity |
Main frame | 1 |
Computer | 1 |
Platinum Circle | 2 |
beaker | 1 |
hook | 1 |
torsion wire | 1 |
Calibration weight(500mg) | 1 |
Product Features:
1.Utilizes advanced electromagnetic balance force sensor for high-precision, repeatable measurements.
2. 5-inch widescreen touchscreen integrates ambient temperature, real-time tension, peak tension, and equivalent tension for intuitive operation.
3.Dual-test design supports platinum plate and ring methods, usable individually or simultaneously.
4.Fully automated workflow eliminates human error: auto-detects liquid interfaces, plots tension curves, locks peak values, displays direct readings, and stops measurements autonomously.
5.Enables full-range auto-calibration with weights, distilled water, and anhydrous ethanol for coefficient fine-tuning.
6.Quiet motorized sample stage with touchscreen-adjustable speed (1–300 mm/min).
7.Quick-release bracket for platinum accessories allows easy installation and on-demand force calibration with standard weights.
8.One-touch tare function ensures stable, zero-drift measurements.
9.Automatic temperature compensation converts readings to 20°C tension values based on water/ethanol references.
10.Data acquisition software compatible with all Windows systems (WIN 7/8/10/XP).
11.Complies with standards including GB/T6541-86, ISO1409-1995, GB/T22237-2008, and more.
12.Features a patented design, ensuring technological uniqueness and competitive edge.
Parameter:
Model | ZL-E1 | ZL-E2 |
Test method | Design platinum plate and platinum ring at the same time, can choose one of them, can also choose two at the same time | |
Control mode | Manual lifting | |
Display mode | LED digital tube display | |
Measuring time | Platinum plate method ≤10s. Platinum ring method ≤50 s | |
Sample size required | Platinum plate method ≥3mL; Platinum ring method ≥5mL | |
Test range (mN/m) | 0-1000 | 0-1000 |
Resolution ratio(mN/m) | 0.1 | 0.01 |
Accuracy(mN/m) | 0.1 | 0.01 |
Repeatability(mN/m) | 0.1 | 0.01 |
Precision of Electronic balance | Domestic 1/1000 grams | Domestic 1/10000 grams |
Weighing system type | Electromagnetic force balance | |
Accuracy automatic calibration | Accuracy automatic calibration: provide weight correction, distilled water and ethanol coefficient correction, temperature correction | |
Data acquisition software | Standard: the configuration software can operate, store, export Excel data and print by computer | |
The micro printer interface | Optional | |
Thermostatic temperature control interface | Optional: it can test the value of surface tension at a specific temperature | |
Equipment weight and size | 20cm*35cm*35cm,7.5kg; | |
Power | 100W |