Liquid Surface Tension Testing Machine/Digital Surface Tension Tester
Technical data:
- Model: JZYW - 200C
- Measuring Range: 0–199.9 mN/m
- Minimum Resolution: 0.01 mN/m
- Platinum Ring Radius: R9.55 mm
- Platinum Wire Radius: r0.3 mm
- Power Supply: 220V 50Hz
- Relative Error: Within ±1%
- Dimensions & Weight: 200×260×300 mm, 10 kg
- Temperature Requirement: (20±5)°C
Performance:
- LCD display for tension values
- Peak value retention function
- Automatic average calculation
- Automated test bed movement with auto-stop feature
Standard:
JB/T9388 ISO/1409
Applicability:
Physical methods are utilized to measure liquid tension. This type of tensiometer is widely adopted in scientific research institutions, universities, and water & power sectors.

Configuration:
Name | Quantity |
Main frame | 1 |
Platinum Circle | 2 |
beaker | 1 |
hook | 1 |
torsion wire | 1 |
Calibration weight(500mg) | 1 |
Instrument calibration:
Verify by the mass method: After installing the instrument (i.e., after completing steps 1 to 4 of the second item), place a small piece of paper on the platinum ring, set it to zero, and put a certain amount of weights on the small piece of paper. At this time, a certain tension value will be displayed. If this value is consistent with the calculated value, it indicates that the instrument has been adjusted properly. If not, open the upper cover and adjust the WK and WK on the circuit board. WK is a fine adjustment. WK is a rough adjustment (as shown in the circuit board diagram). Through repeated adjustments, make it consistent with the calculated value. For example: After adjusting zero, place a 500mg weight on the paper. At this time, the displayed value should be 40.8±0.1. If it is not this value, adjust the potentiometer to make it reach this value, and then the test of the liquid tension value can be carried out. Generally, if the tension value is within the allowable error range, no adjustment is necessary. When the instrument is used for the first time or after being placed for a long time before being used again, or when it is considered that the test results have a large error, the instrument should be calibrated.
Parameter:
Model | ZL-E1 | ZL-E2 |
Test method | Design platinum plate and platinum ring at the same time, can choose one of them, can also choose two at the same time |
Control mode | Manual lifting |
Display mode | LED digital tube display |
Measuring time | Platinum plate method ≤10s. Platinum ring method ≤50 s |
Sample size required | Platinum plate method ≥3mL; Platinum ring method ≥5mL |
Test range (mN/m) | 0-1000 | 0-1000 |
Resolution ratio(mN/m) | 0.1 | 0.01 |
Accuracy(mN/m) | 0.1 | 0.01 |
Repeatability(mN/m) | 0.1 | 0.01 |
Precision of Electronic balance | Domestic 1/1000 grams | Domestic 1/10000 grams |
Weighing system type | Electromagnetic force balance |
Accuracy automatic calibration | Accuracy automatic calibration: provide weight correction, distilled water and ethanol coefficient correction, temperature correction |
Data acquisition software | Standard: the configuration software can operate, store, export Excel data and print by computer |
The micro printer interface | Optional |
Thermostatic temperature control interface | Optional: it can test the value of surface tension at a specific temperature |
Equipment weight and size | 20cm*35cm*35cm,7.5kg; |
Power | 100W |